Omron HBP-1300 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Jednotky krevního tlaku Omron HBP-1300. Omron HBP-1300 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 40
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Professional Blood Pressure Monitor
HBP-1300
Instruction Manual
Table of Contents
Introduction
Intended Use.............................................. 1
Exemptions ................................................ 1
Notes on Safety ......................................... 2
Warnings and Cautions.............................. 3
Using the Unit
Components of the Product ..................... 10
Optional Accessories ............................... 10
Features of the Product ............................11
Features / Functions of Unit..................... 12
Installing the Optional Battery Pack......... 14
Connecting the AC Adapter...................... 15
System Settings
Menu Mode .............................................. 16
Utility Mode .............................................. 17
Non-Invasive Blood Pressure (NIBP)
Measurement
Non-Invasive Pressure Measurement Principles .....
18
Cuff Selection and Connection ................ 19
Applying the Cuff to Patient ..................... 20
Taking the Measurement in "Manual Mode" ....
21
Taking the Measurement in "Auscultation Mode" ...
22
Stopping the Measurement...................... 23
Displaying Last Reading .......................... 23
Maintenance
Maintenance Inspection and Safety Management ...
24
Managing Supplies .................................. 24
Device Maintenance ................................ 24
Accessory Care........................................ 24
Check before Use .................................... 25
Troubleshooting ....................................... 26
List of Error Codes ................................... 28
Disposal ................................................... 29
Limited Warranty
...................................... 30
Specifications
Factory Default Settings........................... 31
Specifications........................................... 31
Manufacturer's Declaration ...................... 33
Thank you for purchasing this OMRON Professional
Blood Pressure Monitor.
Please competely read this Instruction Manual before
using the monitor for the first time.
Read this manual to ensure the safe and accurate
use of the monitor.
For Professional Use
KEEP THIS INSTRUCTION MANUAL
NEAR THE BLOOD PRESSURE
MONITOR FOR FUTURE REFERENCE
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed
healthcare practitioner
HBP-1300.book Page -1 Wednesday, March 7, 2012 9:28 AM
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - Instruction Manual

Professional Blood Pressure Monitor HBP-1300Instruction ManualTable of ContentsIntroductionIntended Use...

Strany 2

8Non-Invasive Blood Pressure (NIBP) measurement Warning CautionIf a cuff is used on a patient with an infection, treat the cuff as medical waste, or s

Strany 3 - Introduction

9IntroductionNote:Setup• Read and understand the manual for each optional accessory. This manual does not contain cautionary information for optional

Strany 4 - General Information

10Using the UnitComponents of the ProductBefore using the unit, make sure that no accessories are missing and that the unit and accessories are not da

Strany 5

11Using the Unit CautionOnly OMRON GS CUFF can be used with this device. Features of the ProductThe OMRON HBP-1300 is an affordable professional blood

Strany 6

12Features / Functions of UnitFront and back of unitMeaning of the Symbols1[START/STOP] button(Power ON/OFF)Power ON / Measure blood pressurePress whe

Strany 7

13Using the UnitLCD Display* Only when the optional battery is installed.1 SYS Displays systolic blood pressure.2 DIA Displays diastolic blood pressur

Strany 8

14Installing the Optional Battery Pack CautionDo not short the positive and negative terminals of the optional battery pack with a wire or other metal

Strany 9

15Using the UnitBattery chargingBattery levelConnecting the AC AdapterAC powerVerify that the power outlet supplies the specified voltage and frequenc

Strany 10 - Warning

16System SettingsThe system settings are divided into two modes, "Menu Mode" and "Utility Mode".Menu Mode"Menu Mode" all

Strany 11 - Optional rechargeable battery

17System SettingsUtility Mode"Utility Mode" allows you to configure the "Auto Power Off" and "Pressure Accuracy Confirmation&

Strany 12 - Using the Unit

HBP-1300.book Page 0 Wednesday, March 7, 2012 9:28 AM

Strany 13 - Caution

18Non-Invasive Blood Pressure (NIBP) MeasurementNon-Invasive Pressure Measurement PrinciplesOscillometric methodThe beat in the pulsation generated by

Strany 14 - Features / Functions of Unit

19Non-Invasive Blood Pressure (NIBP) MeasurementCuff Selection and ConnectionSelecting the cuff Caution• Do not use the cuff if it is damaged or has h

Strany 15 - LCD Display

20Applying the Cuff to the Patient1. Wrap on a bare arm or over thin clothing.Wrap the cuff on a bare arm or over thin clothing. Thick clothing or a r

Strany 16

21Non-Invasive Blood Pressure (NIBP) Measurement CautionMake sure the cuff is wrapped in the correct arm position and is at the same height as the hea

Strany 17 - Connecting the AC Adapter

22Irregular pulse wave detection functionIf the pulse wave interval becomes irregular during measurement, the irregular pulse wave detection icon will

Strany 18 - System Settings

23Non-Invasive Blood Pressure (NIBP) MeasurementStopping the MeasurementTo stop measurement while measurement is in progress, press [START/STOP] butto

Strany 19 - Example:

24MaintenanceMaintenance Inspection and Safety ManagementThe HBP-1300 must be maintained to ensure functionality and to secure the safety of patients

Strany 20 - RADIAL PULSE

25MaintenanceCheck before UseBefore conducting safety checks, be sure to implement the items in the "Device Maintenance" and "Accessory

Strany 21

26TroubleshootingThe power does not turn onCause SolutionIf the unit is being powered by the battery, the battery is not installed or the charge is de

Strany 22 - 1/2"-1"

27MaintenanceAbnormal measurement valueCause / solutionThe causes below are possible. Check the patient by palpation and then repeat measurement.• Bod

Strany 23

1IntroductionIntroductionIntended UseMedical PurposeThe device is a digital monitor intended for use in measuring blood pressure and pulse rate in adu

Strany 24

28List of Error CodesThe alarm lamp flashes when a medium-priority alarm occurs, and lights steadily when a low-priority alarm occurs.To clear an alar

Strany 25 - Displaying Last Reading

29MaintenanceOther problemsDisposalDescriptionAs there is a risk of environmental pollution, follow your applicable Federal, state and local legal reg

Strany 26 - Maintenance

30Limited WarrantyYour OMRON HBP-1300 Professional Blood Pressure Monitor, excluding the arm cuffs is warranted to be free from defects in materials a

Strany 27 - Check before Use

31SpecificationsSpecificationsFactory Default SettingsFactory default settings and backup are as shown below.Backup: Setting is retained even if the p

Strany 28 - Troubleshooting

32Power supplyEnvironmental ConditionsNon-Invasive Blood Pressure (NIBP)* Comparison with auscultation method performed by a trained professional.DIA

Strany 29 - Stethoscope

33SpecificationsManufacturer's DeclarationThe HBP-1300 is intended for use in the electromagnetic environment specified below. The customer or th

Strany 30 - List of Error Codes

34Immunity testIEC60601-1-2 test levelIEC60601-1-2 test levelElectromagnetic environment - guidanceConducted RFIEC 61000-4-6Radiated RFIEC 61000-4-33

Strany 31 - Disposal

35SpecificationsNote:POTENTIAL FOR RADIO / TELEVISION INTERFERENCE (for U.S.A. only)This product has been tested and found to comply with the limits f

Strany 32 - Limited Warranty

36Recommended Separation Distances:Recommended separation distance between portable and mobile RF communications equipment and the HBP-1300The HBP-130

Strany 33 - Specifications

HBP-1300.book Page 37 Wednesday, March 7, 2012 9:28 AM

Strany 34 - Environmental Conditions

2Notes on SafetyThe warning signs and symbol examples indicated below are intended to ensure safe use of the product and prevent damage and injury to

Strany 35

Manufactured by OMRON HEALTHCARE Co., Ltd.Distributed byOMRON HEALTHCARE, INC.1925 West Field Court, Lake Forest, IL 60045, USAMade in China.© 2012 OM

Strany 36

3IntroductionWarnings and CautionsUsage warnings and cautionsSetup Warning CautionDo not use the cuff or AC adapter to lift the unit, it can also caus

Strany 37

4Before use / during use WarningThe unit complies with the EMC standard (IEC60601-1-2). As such, it can be used simultaneously with multiple medical i

Strany 38

5Introduction CautionBefore using the unit, verify that none of the following apply to the patient:- Poor peripheral circulation, noticeably low blood

Strany 39

6Cleaning Warning CautionMaintenance and inspection WarningWhen cleaning the unit, turn off the power and disconnect the AC adapter from the unit.Afte

Strany 40 - 1-877-216-1336

7IntroductionWarnings and cautions for safe measurementOptional rechargeable battery Warning CautionIf battery fluid comes in contact with the eye, im

Komentáře k této Příručce

Žádné komentáře